email WordlPoly home
   
 

SPG 2000 Data Logging Unit

bullet Suitable for our own PT models, and most other electro-hydraulic field welding machines
bullet Measures and reports on every butt weld performed

bullet The printing data-logger is designed and constructed for the measurement of butt welding parameters of PE, PP and PVDF pipes and fittings.
bullet In addition to the control function, the printing data machine helps the operator during all working phases showing on the display and advising with an acoustic signal the pressure and the time to be achieved during all welding cycle phases.
bullet The heating mirror temperature (once the operator has set up the material, diameter and wall thickness of the pipe) is controlled by computer according to the material and wall thickness involved.
bullet At the end of welding, a final print allows the operator or supervisor to check if the welding cycle has been correctly performed.

SPG-2000 General Data

The SPG-2000 data logger is the smart solution for fast recordings of welding and traceability data, according to German and International standards and law.
The German manufactured SPG-2000 is a universal recording box to be used with all butt welding machines from the company Tecnodue, and also from other manufacturers.
The box makes possible the data acquisition and the recording of all welding parameters, which are important for the classification of the joint.
The protocols can be printed out by micro-printer, which is integrated in the box.
Further the records can be transferred to normal PC printers, or directly to the PC.

Features of the SPG 2000 are:
• Simple operating procedure via menu guiding
• Menu guiding in several languages
• Printing in several languages
• Alpha-numeric keyboard with welding diagram
• PC-interface (RS 232), printer interface (Centronics)
• Number of reports: 1500
• Big display with background illumination: 4 x 20 digits
• Self test function after switching on the unit
• Function for configuration of the protocol
• Selectable pressure sensors 100 bar or 250 bar
• Selectable temperature sensors PT 100 or PT 1000
• The welding procedure will be shown via LCD’s

Technical Data
• Input voltage: 100 V – 240 V
• Input frequency: 40 Hz – 80 Hz
• Weight: 4 kg
• Dimension: (240 x 200 x 125)mm
• Protection class box: IP 54

Data Acquisition and Recording
• Type of butt fusion machine, device number
• Cylinder
• Sensors
• Material
• Diameter, wall thickness, nominal pressure
• Angle (at workshop machines)
• Recording number and project number
• Job – or order number (32 digits)
• Welder identification (ISO Standard)
• Date / time of welding
• Ambient temperature
• Movement pressure (actual / nominal)
• Mirror temperature (actual / nominal) on / off switchable
• Adaptation pressure (actual / nominal)
• Bead build-up time (actual / nominal)
• Preheating pressure (actual / nominal)
• Preheating time (actual / nominal)
• Changeover time (actual / nominal)
• Jointing pressure ramp (actual / nominal)
• Jointing pressure (actual / nominal)
• Cooling time (actual / nominal)

Traceability
• Pipe codes (max. 40 digits, ISO)
• Traceability code (26 digits, ISO)
• Weather (DVS)
• Addittional data (max. 20 digits)

Control Functions
• Adaptation pressure
• Mirror temperature
• Preheating pressure
• Preheating time
• Ramp
• Jointing pressure
• Cooling time
• Input power error

 
 